Table 2 Effectiveness of decontamination on Legionella bacterial loading

From: Legionella on board trains: effectiveness of environmental surveillance and decontamination

Month

Mean of load value (CFU/l) (post-decontamination period)

Mean of bacterial load in natural logarithmic numbers

t

p

October 2008

992.2414

6.9000

0.6591

0.2550

November 2008

583.8235

6.3696

1.1843

0.1183

December 2008

397.0000

5.9839

1.6083

0.0541

January 2009

320.1613

5.7688

1.8698

0.0309

February 2009

295.1282

5.6874

2.1259

0.0169

March 2009

306.3265

5.7247

2.3673

0.0091

April 2009

315.3801

5.7538

2.5402

0.0056

May 2009

295.0256

5.6871

2.7428

0.0031

June 2009

417.9909

6.0355

2.7060

0.0035

July 2009

498.4615

6.2115

2.6624

0.0039

August 2009

554.6850

6.3184

2.6735

0.0038

September 2009

592.1561

6.3838

2.6817

0.0037

October 2009

753.6237

6.6249

2.4677

0.0069

November 2009

752.5163

6.6234

2.5500

0.0055

December 2009

748.6751

6.6183

2.6023

0.0047

January 2010

726.0479

6.5876

2.7144

0.0034

February 2010

934.4538

6.8400

2.3195

0.0103

March 2010

962.5000

6.8695

2.3432

0.0097

April 2010

1369.3270

7.2221

1.3341

0.0912

May 2010

1314.9530

7.1816

1.4680

0.0712

June 2010

1521.4860

7.3274

1.0917

0.1376

July 2010

1482.9550

7.3018

1.1885

0.1174

August 2010

1707.7110

7.4429

0.7837

0.2167

September 2010

1697.6230

7.4370

0.8044

0.2107

October 2010

1684.2690

7.4291

0.8432

0.1996

November 2010

1635.7890

7.3999

0.9556

0.1697

December 2010

1719.8530

7.4500

0.8037

0.2109

January 2011

1721.6250

7.4510

0.8141

0.2079

  1. [In Table 2 are reported the results of the unpaired t-tests performed to compare the mean value of the bacterial load in the pre-decontamination period (grand mean: 2142.7840 CFU/L – 7.6698 in logarithmic value) with the ones of the post-decontamination period].