Skip to main content

Table 5 Operational parameters of the incinerator and final disposal of ash

From: Current practices of waste management in teaching hospitals and presence of incinerators in densely populated areas

Variables

Govt. tertiary hospitals % (n = 3)

Private teaching hospitals %(n = 6)

Overall hospitals % (n = 9)

Fisher’s Exact test

p-value (< 0.05)

Type of incinerator

 Single chamber

0

50

33.33

4.44

0.143

 Double chamber

33.33

50

44.45

  

 Multi-chamber

66.67

0

22.22

  

Temperature range (800-1200 °C) is achieved in both chambers before waste introduced

 Upto range

33.33

50

66.67

0

1

 Not upto range

66.67

50

33.33

  

Chimney height (> 4 m)

 Up to standard

33.33

50

66.67

0

1

 Not up to standard

66.67

50

33.33

  

Incineration operation manual

 Available

66.67

66.67

66.67

0

1

 Not available

33.33

3.33

33.33

  

Incinerated waste daily/monthly record

 Available

0

0

0

  

 Not available

100

100

100

  

Type of arrangement available for final disposal of ash

 Container

100

83.33

88.89

0

1

 Cemented pits

0

16.67

11.11

 Â