Skip to main content

Table 3 Paired sample t-test results of correct times to sound and light stimuli

From: A simulation experiment study to examine the effects of noise on miners’ safety behavior in underground coal mines

 

Pairing Difference

t

Degree of Freedom

Significant P (Two-tailed)

Average value (E)

Standard Deviation

Standard Error Mean

95% Confidence Interval for the Difference

Lower Limit

Upper Limit

Sound Control - 60 dB

.785

5.146

1.375

−2.185

3.757

.571

13

.578

Sound Control - 70 dB

1.285

9.769

2.611

−4.355

6.926

.492

13

.631

Sound Control - 80 dB

7.785

11.178

2.987

1.331

14.239

2.606

13

.022

Sound Control - 90 dB

11.461

10.829

3.003

4.917

18.005

3.816

12

.002

Sound Control - 100 dB

4.750

2.764

.977

2.438

7.061

4.860

7

.002

Sound Control - 110 dB

8.125

3.270

1.156

5.390

10.859

7.027

7

.000

Sound Control - 120 dB

11.500

2.828

1.000

9.135

13.864

11.500

7

.000

Light Control - 60 dB

−1.071

2.758

.737

−2.664

.521

−1.453

13

.170

Light Control - 70 dB

1.142

3.483

.930

−.868

3.153

1.228

13

.241

Light Control - 80 dB

4.928

3.852

1.029

2.704

7.152

4.787

13

.000

Light Control - 90 dB

8.153

5.096

1.413

5.074

11.233

5.768

12

.000

Light Control - 100 dB

4.250

1.281

.453

3.178

5.321

9.379

7

.000

Light Control - 110 dB

7.125

2.100

.742

5.369

8.880

9.596

7

.000

Light Control - 120 dB

10.000

2.618

.925

7.810

12.189

10.801

7

.000