Skip to main content

Table 4 Relationships between sick-building-syndrome symptoms and indoor air quality (IAQ) perceptions of workers in underground shopping centers

From: Perception of indoor air quality (IAQ) by workers in underground shopping centers in relation to sick-building syndrome (SBS) and store type: a cross-sectional study in Korea

 

Skina

Eye irritationb

Respiratoryb

Generala

OR (95% CI)

OR (95% CI)

OR (95% CI)

OR (95% CI)

Stuffy odor

 No

1.00

1.00

1.00

1.00

 Yes

2.89 (1.73–4.83)***

6.39 (3.40–12.01)***

4.79 (2.56–8.97)***

6.03 (3.12–11.63)***

Unpleasant odor

 No

1.00

1.00

1.00

1.00

 Yes

2.08 (1.23–3.51)**

4.06 (2.15–7.67)***

4.00 (2.05–7.81)***

4.29 (2.19–8.41)***

Pungent odor

 No

1.00

1.00

1.00

1.00

 Yes

3.07 (1.72–5.50)***

5.16 (2.44–10.89)***

7.33 (3.09–17.4)***

4.46 (2.11–9.42)***

Moldy odor

 No

1.00

1.00

1.00

1.00

 Yes

2.29 (1.19–4.41)*

3.65 (1.64–8.13)**

3.81 (1.59–9.09)**

2.93 (1.28–6.71)*

Tobacco smoke odor

 No

1.00

1.00

1.00

1.00

 Yes

1.81 (0.99–3.32)

2.45 (1.21–4.99)*

4.04 (1.78–9.13)***

3.29 (1.54–7.02)**

Dry air

 No

1.00

1.00

1.00

1.00

 Yes

5.14 (3.07–8.60)***

7.07 (3.99–12.50)***

7.84 (4.28–14.35)***

6.21 (3.47–11.11)***

Humid air

 No

1.00

1.00

1.00

1.00

 Yes

2.16 (1.18–3.93)*

2.40 (1.22–4.71)*

3.11 (1.47–6.58)**

2.37 (1.18–4.76)*

Categorized IAQ perception scorec

 Category 0

1.00

1.00

1.00

1.00

 Category 1

5.62 (2.85–11.06)***

4.96 (2.68–9.18)***

5.26 (2.83–9.76)***

3.80 (2.07–6.98)***

 Category 2

9.92 (4.91–20.05)***

19.33 (8.75–42.71)***

19.39 (8.47–44.39)***

12.89 (5.96–27.9)***

p-for trend

< 0.001

< 0.001

< 0.001

< 0.001

  1. *P < 0.05; **P < 0.01; ***P < 0.001
  2. aOR was adjusted for sex, age, smoking status, hours worked per day, and type of store
  3. bOR was adjusted for sex, age, smoking status, and type of store
  4. cCategory 0 = score of 0; Category 1 = score of 1to 2; Category 2 = score of 3 to 7