Skip to main content

Table 6 Sensitivity and specificity of each activity monitor for moderate and vigorous physical activity

From: Validity of SC-StepRx pedometer-derived moderate and vigorous physical activity during treadmill walking and running in a heterogeneous sample of children and youth

Monitor

Moderate PA

Vigorous PA

Moderate and Vigorous PA

 

Sensitivity

Specificity

Sensitivity

Specificity

Sensitivity

Specificity

SC-StepRx (100, 120)

16.4

89.9

100.0

74.3

98.8

84.2

SC-StepRx (110, 130)

44.3

97.1

100.0

88.6

92.9

96.5

SC-StepRx (120, 140)

27.9

98.6

45.8

98.9

77.6

99.1

Walk4Life MVP (100, 120)

16.4

91.3

95.8

77.1

97.7

87.7

NL-1000 (4–9)

-

-

-

-

85.9

97.4

Actical

80.3

84.1

37.5

97.1

91.8

91.2

ActiGraph GT3X (Evenson)

26.2

92.0

70.8

82.9

87.1

92.1

ActiGraph GT3X (Treuth)

39.3

92.0

41.7

92.6

76.5

98.3

ActiGraph GT3X (Freedson)

62.3

89.1

37.5

94.9

87.1

96.5

  1. PA: Physical activity.